iC60H – earth leakage circuit breaker – 1P + N – C curve – 40 A – 30 mA – 240 V
Main circuit breaker application
Distribution
range
Acti 9
product name
Acti 9 iC60 RCBO
product or component type
Residual current breaker with overcurrent protection (RCBO)
device short name
IC60H RCBO
poles description
1P + N
40 A at 50 °C
earthing system
TN
curve code
C
earth-leakage sensitivity
30 mA
breaking capacity
10000 A Icn at 240 V AC 50/60 Hz
Complementary neutral position
Left
number of protected poles
1
device location in system
Outgoer
network type
AC
network frequency
50 Hz
240 V AC 50/60 Hz
trip unit technology
Thermal-magnetic
residual current tripping technology
Voltage dependent
earth-leakage protection time delay
Instantaneous
earth-leakage protection class
Type A
Icw: 250 A during 8/20 µs impulse withstand [Ics] rated service breaking capacity
7500 A at 240 V AC 50/60 Hz
limitation class
3
400 V AC 50/60 Hz [Uimp] rated impulse withstand voltage
4 kV
surge current
250 A
suitability for isolation
Yes
contact position indicator
Yes
control type
Toggle
local signalling
ON/OFF indication
mounting mode
Clip-on
mounting support
DIN rail
comb busbar and distribution block compatibility
NO
9 mm pitches
2
height
110 mm
width
18 mm
depth
77.5 mm
net weight
205 g
colour
White
mechanical durability
20000 cycles
electrical durability
5000 cycles
provision for padlocking
Padlockable with padlock Ø 4 mm
locking options description
ON/OFF locking facilities
connections – terminals
Screw clamp terminal (top) 1…25 mm² rigid without cable end
Screw clamp terminal (top) 1…16 mm² flexible
Screw clamp terminal (bottom) 1…16 mm² rigid without cable end
Screw clamp terminal (bottom) 1…10 mm² flexible
wire stripping length
Power circuit: 13 mm for bottom connection
Power circuit: 14 mm for top connection
tightening torque
Power circuit: 3.5 N.m top
Power circuit: 2 N.m bottom
earth-leakage protection
Integrated
Environment standards
BS EN 61009-1
IEC 61009-2-2
AS/NZS 61009.1
IEC 61009-1
IP degree of protection
IP20
tropicalisation
2
relative humidity
95 % at 55 °C
ambient air temperature for operation
-15…60 °C
ambient air temperature for storage
-40…85 °C
Offer Sustainability Sustainable offer status
Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Compliant
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information