The Complete czone system in a simple box designed for manufacturers, installers, special purpose vehiclesand also those of you like to DIY,
No more complicated cables to switch and fuse panels, the COI will replace all of it via it’s innovative interface and light weight NMEA 2K network cabling. It is the perfect solution for users wanting automation and complete control of their electrical system and gives them the ability to pin point any issues found on today’s on board systems.
The Combination Output Interface (COI) incorporates multiple input and output devices in to one module, offering a compact and intelligent replacement for traditional DC fuse boxes and circuit breaker panels with digital switching technology.
CZone is a pioneer in digital switching, a proven CANbus technology where a single data cable is used to operate clusters of switches. Provides a high density 30 channel module which minimizes installation, interconnections and footprint, while delivering best value per circuit.
Easy installation
The COI features the same proven, rugged CZone design including IPX5 water ingress protection and complete mechanical fuse plus bypass on all circuits as required by ABYC/CE. Industry standard Deutsch connectors provide “plug and play” installation.
The COI is essentially a complete CZone® system in a single, rugged housing, making it a cost effective solution where space and budgets are limited. By using fewer connection points along with industry-standard ‘plug & play’ Deutsch connectors, the COI is very easy to install.
A USB port has been added to improve remote serviceability and allow for easy upgrades, whilst a high power 150-amp unit fields enough energy for modern domestic appliances that may run through the electrical system.
Quick access and overview
A CZone touchscreen is used to operate the system centrally, and as the ABYC and CE safety authorities require every circuit to have both a fuse and a bypass, this is provided within the COI. Each ATC fuse can be simply withdrawn to isolate a circuit, and pushed into a different position to create a bypass. To aid identification of the individual fuses, an adhesive circuit label is available, which is printed to a customer’s exact requirements. A clear plastic cover protects the fuses, although a large clipping system provides fast access. Red and green LEDs indicate a circuit’s status at a glance.
Partnered with either a dedicated CZone display, or with a multi functional display from one of our industry leading integration partners ( Raymarine, B&G, Furuno, Garmin, Lowrance, Simrad), the COI heralds a new era in providing simple, intuitive control over the increasingly complex systems found on today’s applications.
Multiple protection
The Combination Output Interface has multiple layers of protection provided by software, hardware and mechanical means for ultimate reliability. The casing is built to the IPX5 water ingress standard. An optional cable cover is available to hide the cable glands.
Other features include high power pump channels to allow manual control, plus ‘pump running’ feedback, from a single channel without the need for additional wiring. In addition, the COI provides six digital switch inputs (wiper, horn, etc.), eight analogue inputs (starter battery, fuel gauge sender, etc.) twelve low current (10 A) outputs (courtesy lights, anchor light, etc.) and four high current (25 A) outputs (bilge and water pumps).
There is also a Combination Output Interface without connectors available for refit or service purposes.